Minerval A12

Acoustic absorption:12mm: αw = 0.80 | 15mm: αw = 0.90

Fire reaction: Euroclass A1 under EN 13501-1

Indoor Air Quality: Products in the Minerval® range have reached Class A in the Indoor Air Quality marking system, which became mandatory in France on 1 January 2012.

Humidity performance:  No sagging, humidity resistant

CE marking:DOP N˚: 0007-01 for A Edge | DOP N˚ : 0007-05 for E Edge

Environment

  • Mineral wools are recyclable and the vast majori-ty of four production waste is recycled.
  • Environmental and Health Declaration Sheets are available at www.inies.fr.
  • Eurocoustic is ISO 14001:2004 certified (Environmental Management Systems).

Health

Stone wool panels are made from fibre exempt from carcinogenic classification (EU Regulation 1272/2008 amended by EU Regulation 790/2009. The International Agency for Research on Cancer states that mineral wool is not classifiable as to its carcinogenity to humans (group 3).

Cleaning

Use a soft brush or a vacuum cleaner to clean the surface and thereby help extend the life of the ceilings.

Installation

  • Refer to the instructions in DTU 58.1 and the NFP 68203-1 and 2 standards and other prevailing DTUs based on the nature of the  area treated.
  • Air circulation between the spaces and the ple-num is recommended to balance temperature and pressure on both sides of the ceiling.
  • Minerval® ceilings are installed on T15 or T24 grids.
  • Panels can be cut with a cutting blade without generating noise or dust.
  • The direction in which the panels should be in-stalled is marked on the rear side of the panel.

Brochures


Catalog


Certificates


Test Reports

Product presentation videos


Installation videos