Acoustic absorption:12mm: αw = 0.80 | 15mm: αw = 0.90
Fire reaction: Euroclass A1 under EN 13501-1
Indoor Air Quality: Products in the Minerval® range have reached Class A in the Indoor Air Quality marking system, which became mandatory in France on 1 January 2012.
Humidity performance: No sagging, humidity resistant
CE marking:DOP N˚: 0007-01 for A Edge | DOP N˚ : 0007-05 for E Edge
Environment
- Mineral wools are recyclable and the vast majori-ty of four production waste is recycled.
- Environmental and Health Declaration Sheets are available at www.inies.fr.
- Eurocoustic is ISO 14001:2004 certified (Environmental Management Systems).
Health
Stone wool panels are made from fibre exempt from carcinogenic classification (EU Regulation 1272/2008 amended by EU Regulation 790/2009. The International Agency for Research on Cancer states that mineral wool is not classifiable as to its carcinogenity to humans (group 3).
Cleaning
Use a soft brush or a vacuum cleaner to clean the surface and thereby help extend the life of the ceilings.
Installation
- Refer to the instructions in DTU 58.1 and the NFP 68203-1 and 2 standards and other prevailing DTUs based on the nature of the area treated.
- Air circulation between the spaces and the ple-num is recommended to balance temperature and pressure on both sides of the ceiling.
- Minerval® ceilings are installed on T15 or T24 grids.
- Panels can be cut with a cutting blade without generating noise or dust.
- The direction in which the panels should be in-stalled is marked on the rear side of the panel.